A metal mask is reusable, which is why it beats a photolithography step for prototyping and for materials that cannot survive resist chemistry. But reusable is not the same as immortal. Every run and every clean takes something out of the part.
Most people notice the problem the wrong way round. A process that used to work starts producing slightly wrong features, and the first suspicion falls on the latest batch of masks. Usually the masks are fine, and the accumulated drift is in the old one sitting in the cabinet.
Mechanism 1: build-up on the aperture walls
The mask does not only shadow the vapour, it also collects it. Every run deposits material on the face and inside the aperture walls. Apertures get progressively narrower, corners fill in, and the effective edge becomes less defined. Thick build-up also creates a flaking risk, which is one source of particle contamination on the substrate.
This is the mechanism that responds best to routine cleaning. It is also why the honest answer to "how many times can I reuse this" depends mainly on what you are depositing, not on what the mask is made of. An easily soluble metal film is trivial to strip. A hard, adherent oxide or alloy is not.
Mechanism 2: damage during cleaning
Cleaning is where most masks are actually killed, not deposition. Three habits account for nearly all of it:
- Abrasive wiping — dragging a wipe across the aperture array rounds the edges and can bend fine webs permanently. Always work outwards from features, never across them.
- Over-aggressive chemistry — strong acid attacks the base metal as happily as the deposit. Repeated stripping dissolves the aperture walls a little at a time.
- Long ultrasonic cycles — cavitation is violent. Thin masks, particularly below about 0.1 mm, can be dimpled, creased or cracked, and narrow webs fail first.
Mechanism 3: corrosion
As covered in our note on material choice, Invar36 has no chromium and is not stainless. It stains and pits. Once corrosion starts on an aperture edge, the edge is no longer the shape you measured, and no amount of cleaning brings it back.
Storage prevents most of this. Never put a mask away damp. Dry it fully, wrap it, interleave it with soft material so masks do not abrade each other, and keep it flat in a low humidity cabinet. It takes thirty seconds and it is the cheapest life extension available.
Mechanism 4: stress relief from thermal cycling
Rolled strip carries residual stress, and etching removes metal unevenly, which redistributes it. Each heating cycle lets some of that stress relax, so the part finds a slightly new shape. This shows up as slow, irreversible change in flatness and, in fine arrays, in relative positions.
This is the one you cannot clean away. It is also why a mask that has been through hundreds of cycles should be re-measured rather than assumed good, and why we recommend keeping the first article inspection report as the reference you compare against.
A fifth, unglamorous one: handling
Masks get damaged on the bench far more often than in the chamber. Flexing a large thin sheet to get it into a box puts a permanent crease in it. Stacking them without interleaving scratches the faces. Lifting by one corner when the part wants to be supported across its width puts a bend along the webs.
Handle large or thin masks flat, with both hands, and store them that way.
Reasonable expectations
With sound practice, it is reasonable to expect the measured aperture dimensions to stay within a few microns over the first ten to twenty cycles on a well-behaved process. Past that, inspect rather than assume. Aggressive cleaning or thick build-up can move an edge by more than ten microns in a handful of cycles. Those numbers vary enormously with the process, so measure rather than trust a rule of thumb.
| Cause | Symptom | What helps |
|---|---|---|
| Abrasive cleaning | Rounded edges, blurred features | Wipe outwards from features, never across |
| Wet storage | Staining, edge pitting | Dry fully, wrap, low humidity cabinet |
| Thick build-up | Apertures closing, flaking particles | Clean on a routine schedule, not when it looks bad |
| Thermal cycling | Slow drift, flatness loss | Unavoidable; re-measure periodically |
| Handling | Creases, bends, cracked webs | Handle flat, store flat, interleave |
| Over-aggressive acid | Uniform edge loss, thinning webs | Mildest chemistry that works; test first |
When to retire it
- Visible edge damage under magnification
- Build-up that no longer responds to your normal cleaning cycle
- Measured drift beyond your overlay budget
- Permanent loss of flatness that tension mounting cannot take out
- Corrosion pitting close to any feature
- Cracks, particularly at webs
A good operating discipline is to photograph the aperture area every ten runs and re-measure the critical dimensions every twenty. Keep the images with the first article inspection report and you will be able to see drift coming instead of discovering it in your data.
Worth saying plainly: a replacement mask costs a small fraction of a failed experimental run. If there is doubt, replace it. Most labs are far too conservative about retiring masks and pay for it in unexplained process variation.
Ordering replacements against an existing drawing is straightforward — send us the drawing number and revision through the upload form and we will match it. If you lose the drawing, we keep it on file under the original reference.