What we can hold, what depends on your geometry, and the design rules that keep a mask manufacturable. Figures below are typical production capability; the final numbers are confirmed against your drawing.

Capability

Manufacturing specification

General capability, custom metal shadow masks
MaterialsInvar36 (Fe-36Ni), stainless steel 304/316, molybdenum, nickel, copper, aluminium
Thickness range0.02 mm to 2.5 mm
Standard thickness0.1 mm Invar36
Position accuracy±20 µm over the full panel
Feature toleranceFrom ±5 µm, geometry dependent
Minimum feature width0.1 mm for standard designs; finer apertures by engineering review
Maximum panel size600 × 600 mm standard, larger on request
Corner radiusApproximately 10 – 20 µm, process dependent
Edge qualityBurr-free, stress-free, supplied flat
Alignment featuresFiducials, tabs and holes in the same operation
Accepted file formatsDXF (preferred), DWG, STEP, PDF, Gerber, or a dimensioned sketch
Sample lead time1 – 3 working days
Batch lead timeConfirmed with the order, repeat batches by schedule
Minimum orderOne piece
InspectionFull dimension report supplied with each batch
Material data

Invar36 properties

Why this alloy is specified for evaporation masks.

Invar36 (Fe-36Ni) typical properties
Nickel content36%
Coefficient of thermal expansion~1.2 × 10-6 /K (20 – 100 °C)
Comparison to stainless 304Roughly one tenth the expansion
Density~8.1 g/cm3
Magnetic responseFerromagnetic
Typical useMasks requiring dimensional stability under repeated heating
DocumentationMill certificate available on request
Practical consequence. When a stainless mask heats up during deposition it grows, and the pattern drifts relative to the substrate. An Invar36 mask moves roughly ten times less, which is what keeps registration intact across a multi-layer stack and across repeated runs.
Design guidelines

Rules that keep your mask manufacturable

Follow these and your drawing will quote quickly and cut cleanly. Break them and we will tell you what to change.

1. Watch the thickness to feature ratio

Keep thickness between one and three times your smallest feature. A 50 µm aperture wants a 30 to 100 µm thick mask. Go thicker and the aperture walls shadow the vapour, softening the deposited edge and distorting the shape.

2. Sharp inside corners are not possible

Both laser cutting and chemical etching round inside corners, typically to a 10 – 20 µm radius depending on thickness. Design with a radius, or accept the one the process produces.

3. Send vector, not raster

DXF is preferred. DWG, STEP, PDF and Gerber are all workable. A photograph or a screenshot is not, unless it carries clear dimensions, because we would have to redraw it and guess at tolerances.

4. Mark the critical dimensions

Not every dimension needs a tight tolerance, and holding all of them tight costs money and yield. Tell us which features are functional and which are clearance, and we will apply tolerance where it actually matters.

5. Include your holder geometry

The mask outline should match your substrate holder or carrier. Send the holder drawing if you have it, or the substrate size and how the mask is clamped. Alignment features are cheaper in the mask than in a fixture.

6. Plan for multi-layer registration

If you are depositing a stack, all masks in the set should share the same datum. Send the full set as one package and we will hold the alignment features consistent across all of them.

Questions

Frequently asked

What is the minimum feature size you can make?
For standard 0.1 mm masks we recommend apertures of 0.1 mm and above; anything finer goes through an engineering review first. The real limit is not the cutting process but the thickness to feature ratio: if your aperture is 50 µm, the mask should be no thicker than about 150 µm, otherwise the walls shadow the vapour flux.
Why is Invar36 used for shadow masks instead of stainless steel?
Invar36 expands at roughly 1.2 × 10-6 per kelvin against about 17.3 × 10-6 for stainless 304, close to a factor of ten. Evaporation sources heat the mask, and a mask that grows shifts its pattern relative to the substrate. Invar36 keeps registration through repeated heating cycles, which is why it is specified where alignment has to hold.
What tolerance can you hold on a 0.1 mm Invar36 mask?
Position accuracy of ±20 µm across the panel, with feature tolerance from ±5 µm depending on geometry. We confirm the achievable figure against your drawing before quoting, rather than quoting a generic number and arguing about it later.
What file formats do you accept?
DXF is preferred. We also work from DWG, STEP, PDF and Gerber. If you have no CAD file, a dimensioned sketch showing overall size, thickness, aperture sizes and gap spacing is enough for us to produce a drawing for your approval.
Do you have a minimum order quantity?
No. One piece is a valid order. Most of our research customers order single masks or small sets, and repeat batches only once the design is settled.
How long does a sample take?
One to three working days for a first article, plus shipping. Design changes after you have seen the sample are usually turned around faster because the process parameters are already established.
Can you make masks larger than 600 mm?
600 × 600 mm is our standard maximum. Larger panels are possible but depend on material availability and flatness requirements, so send the size and we will advise before quoting.
How should a mask be cleaned between runs?
It depends on what you are depositing. In general, avoid aggressive mechanical scrubbing on thin gauges, since it distorts the apertures. Tell us your deposited material and we will suggest a cleaning approach that does not shorten the mask life.

Further reading

Selected technical notes from our engineering team.

Not sure your design will cut?

Send it anyway. A manufacturability review costs nothing and takes 24 hours.

Upload Your Drawing